HomeMedical SpecialtiesGeriatrics and AgingSmart wearables for faster cardiac arrest emergency response

Smart wearables for faster cardiac arrest emergency response

Published on

Prototypes of smartwatches and rings are driving forward advances in wearable technology that instantly alert emergency personnel.

A pioneering study led by Vancouver Coastal Health Research Institute (VCHRI) researcher Dr. Calvin Kuo and Dr. Mahsa Khalili has demonstrated that consumer wearable technology may hold the key to transforming how out-of-hospital cardiac arrests (OHCAs) are detected, potentially saving countless lives. With more than 4.4 million OHCAs occurring globally each year — and over 75 per cent of them unwitnessed — the study’s findings pave the way for Canadian-made technological advances to alert emergency response personnel as soon as a cardiac arrest occurs.

“This research shines a spotlight on a critical barrier to timely care in OHCA: the absence of a witness,” explains VCHRI researcher Dr. Brian Grunau, head of the Canadian Saving Cardiac Arrest Victims Everywhere (CanSAVE) research excellence cluster overseeing the award-winning broader project that encompasses the present study. “When unnoticed, the chance of surviving a cardiac arrest drops dramatically to almost zero.”

The study involved integrating the photoplethysmogram (PPG) sensors commonly used in smartwatches and fitness trackers into novel, wearable PPG heart rate monitoring devices. 

Research in real-world settings is needed to further advance wearable technology.

The research team tested three different PPG sensor prototypes on 31 healthy adult participants who wore the devices on their wrists, fingertips and base of their fingers simultaneously. Researchers used an advanced machine learning computer algorithm — a type of artificial intelligence — to test prototype performance.

The PPG device prototypes were tested under three conditions: normal cardiac state, occlusion and off-body. Occlusion tests involved restricting blood flow through participants’ arms to mimic a pulseless cardiac arrest event. The off-body scenario tested the performance of devices when not worn by the participant, attempting to capture instances of false positives when the device may erroneously detect cardiac arrest when the wearer takes it off.

“This technology could be used by anyone, with particular clinical indications for people at risk of heart disease and cardiac arrest.”

Data collected from testing the PPG fingertip prototype under ideal conditions achieved almost a 94 per cent detection rate for occluded, pulseless states — approaching the level of sensitivity needed for clinical utility. Devices using finger-based PPG sensors consistently outperformed wrist-worn models, which only identified approximately 78 per cent of pulseless events under ideal conditions. 

However, when used under conditions more similar to real-world settings, fingertip prototype performance in detecting pulseless events dropped to 90 per cent and wrist prototype performance dropped to 44 per cent.

“In this proof-of-principle study, we were able to show that the technology can detect cardiac arrest under ideal, controlled conditions.”

“Given the success of this study, our team has embarked on national clinical trials to test the efficacy of these wearables — including prototypes with enhanced technology and additional functionality — under real-world conditions in clinical and other settings,” notes Khalili. 

Examples of the wrist, fingertip and base of the finger prototypes tested in the study.

On top of alerting emergency service personnel, subsequent iterations of the technology could also send vital medical information to first responders for a rapid response informed by the unique needs and health status of each patient.

The study also highlighted the limitations of current wrist-worn consumer devices. Nearly half of wrist PPG recordings were of low quality, undermining detection accuracy. This information is a wake-up call to improve the technology’s hardware and data processing algorithms further before moving to the next, highly anticipated step of commercialisation, Khalili says. 

The implications for health care systems are profound. Equipping everyday people with passive cardiac monitoring could significantly improve early recognition and emergency medical service activation in unwitnessed OHCA cases — dramatically increasing survival rates.

“Our study demonstrates the concept and the challenges that need to be addressed to make accurate cardiac arrest detection using smartwatches a reality in Canada,” says Kuo. “With continued innovation, wearable technology can evolve from fitness trackers into powerful medical tools, revolutionizing cardiac care and saving lives when every second counts”.

Latest articles

Proving Mental Health LTD Claims: Why Trauma-Informed Legal Help Matters

The Hidden Struggle Nearly all of our clients suffer some degree of mental illness; whether...

How a malaria-fighting breakthrough provides lasting protection

HN Summary • New Tool: WHO recommended the first new class of vector control products...

Hospital’s first MRI machine brings advanced care closer to home

First MRI Machine, Bringing Advanced Care Closer to Home Collingwood General and Marine Hospital (CGMH)...

Sterilization failure halts surgeries, offers lessons for hospitals nationwide

HN Summary •Issue: Hard water caused sterilization failures, disrupting surgeries. •Response: Emergency surgeries protected; instruments sent...

More like this

Hospital’s first MRI machine brings advanced care closer to home

First MRI Machine, Bringing Advanced Care Closer to Home Collingwood General and Marine Hospital (CGMH)...

Study linking depression to specific altered brain cells opens door to new treatments

Researchers at McGill University and the Douglas Institute have identified two specific types of...

Canadian first: Heart transplant after death by circulatory criteria

In another Canadian first, a multidisciplinary team from UHN's Peter Munk Cardiac Centre and...

AI-radar system tracks subtle health changes

New tech from Waterloo researchers allows doctors to detect early signs of health issues...

Southlake Health introduces new Emergency Department wait-time clock

HN Summary: • Southlake’s ED was originally built in 2003 to handle just over 80,000...

Easy to install and retrofit home emergency call sysytem with EnOcean technology

In care facilities and serviced apartments quick help in an emergency counts. Modern home...